BRAND
APPLICATION INDUSTRY
Products
TOC Analyzer
TOC Analyzer
General
TOC (Total Organic Carbon), which directly shows the total organic content, is regarded as a key factor to evaluate pollution potentials of organic compound in water.
Our TOC can meet requirements for application in water analysis, environment monitoring, pharmaceutical production, quality control, processing control etc.
So far, we have 2 models TOC: TOC-2000 (Catalytic combustion oxidation) and TOC-3000 (Wet chemical oxidation by UV) which are widely used for quality control of drinking water, industrial water, sewage and waste water. Meanwhile, it has wide application in monitoring of River, Lake, Sea and surface water.
Features
* Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self testing and flow speed control to ensure high performance and safe operation.
* Low current system design also ensures operation safety.
* Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data.
* Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.
* Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s safety
* Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data.
* TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly improves performance.
Specification
Model |
TOC-2000 |
TOC-3000 |
Detector |
NDIR |
NDIR |
Parameters |
TC, TIC, TOC |
TC, TIC, TOC, NPOC |
Digestion Mode |
High Temperature Combustion |
Wet chemical oxidation by UV |
Operation Mode |
PC Control |
PC Control |
Application |
Liquid Sample, Gas Sample(coming soon),
Solid Sample(coming soon) |
Liquid Sample,
Gas Sample(coming soon) |
Gas Requirement |
Oxygen, Nitrogen≥99.995% |
Nitrogen≥99.995% |
Measurement Range |
0-30000mg/l |
0-10000mg/l |
Detection Limit |
50μg/l |
5μg/l |
Repeatability |
3% |
3% |
Maximum Salinity |
85g/l |
85g/l |
Power |
220±10V,50/60HZ, 1KW |
220±10V,50/60HZ, 1KW |
Size |
430*455*440mm |
430*455*440mm |
Sample measurement processing monitoring
* Set different Name, concentration and sample volume
* Real-time sample reaction
* On-line AVG and RSD calculation of testing results
Display and monitoring of sampling
* Sampling volume real-time monitoring
* Automatic sample draining monitoring
* Real time display and monitoring for heating, cooling and temperature
* Auto Switch of Sampling and Draining
* Acidification operation by peristaltic pumps
Scanning Curves
* Samples Curves shows in the same coordinate system for easy reading of repeatability
Parameter Setting Interface
* Settings for heating and cooling temperature; acidification sampling and draining time; Basic setting for Pump, valve and temperature control
* Press "TC" Clean, the system will automatically start drain-add Sodium persulfate – Draining – Sampling -- Draining
Halogen Scrubber Design
* Reduce Halogen and Moisture
* Avoid any effect on the results caused by impurities
Four In One TIC Reactor Design
* Helpful to remove inorganic carbon by acidification and heating digestion
* Cooling function to remove moisture in carbon dioxide
* Gas buffer design to avoid part broken caused by high pressure
* High moisture removal function
High Temperature Pyrolysis system
* Complete pyrolysis for samples with high temperature
* Set different pyrolysis temperature for various samples
NDIR High Efficiency Detector
* Detector with special surface treatment technology to ensure ideal performance
* 24 bit A/D Converter to ensure stable data, low noise, wide measurement range and high speed
* 32bin signal processing technology to ensure the instrument’s constant temperature function with 0.01℃ temperature tolerance.